A failed Level 2 report, read line by line and priced on paper.
Get the findings priced
Tell us the address and which findings are on the report, in your own words. We call back and arrange a visit to price them.
The findings we see most
These are the items that appear again and again on failed reports around San Dimas. Your report may use different words, but most findings fit one of them.
- Cracked, offset or missing clay tile in the flue
- Gaps where the stack meets the roof, or rusted metal there
- A split or crumbling concrete slab on top of the brick
- No hood over the flue opening
- Open or washed-out mortar joints high on the stack
- Wood trim or a mantel too close to the opening
- Movement: cracks through several courses or a lean
What each one usually needs
Flue damage is fixed by repairing the tile or running a new lining down the old flue. Roof-line gaps take new metal, and on a wide stack, a small saddle on the high side so water stops pooling. A split top slab is coated if the cracks are fine and recast if it is broken through. A missing hood is fitted. Open joints are cut out and repointed with a mortar that suits the brick. Trim too close to the fire is moved or replaced with something that does not burn.
Movement is the one that varies most. Depending on what the camera and the roof show, it may mean bracing the stack to the house, relaying the top courses, or rebuilding from the roofline. We set out the options side by side and say which we would choose.
What can wait
Not everything on a failed report has to happen before the next fire. Flue damage, wood too close to heat and loose brick at the top come first. Water items, like open joints and a split top slab, should be done before the rains. Cosmetic items, like staining or a dated face, can wait as long as you like.
Our estimate puts one of those marks on every line, so you can spend on safety now and plan the rest. If the report came from a sale, the buyer may push for everything at once; the marks help both sides see what really matters.
Published prices for the usual fixes
These fixes come up on failed reports often enough that we print a price. A hood over the flue is quoted after we measure. The wording is ours.
- Water entry traced and stopped
- $550 to $3,300
- Saddle on the high side of a wide stack
- $440 to $990
- Saddle plus new metal on every side
- $660 to $1,650
- Sealed gas box set into the old opening, lined
- $2,750 to $5,500
- Camera re-check once the work is done
- $385
Flue relining, top slab work, repointing, dampers, chase tops and roof-line metal on its own carry no printed price. Their figures sit on your own estimate, line by line.
Questions about a failed report
Can I use the fireplace before the repairs?
Not if the report lists flue damage, heavy tar or wood too close to the opening. For water items alone, the risk is to the masonry rather than to people, but we would still fix those before the rains.
Can you work from the report I already have?
We read your report, then visit to see the findings ourselves before pricing. If you want our own report on file as well, that is booked as a separate inspection.
Is a new lining always needed for cracked flue tile?
Not always. A few damaged tiles can sometimes be repaired. Widespread cracking usually means a new lining. The estimate shows both where both are possible.
Why would I turn the fireplace into a gas unit instead?
If the flue needs relining anyway, a sealed gas box with its own lining fixes the finding and changes how the room heats. Some owners prefer it; others keep wood. We price both.
Will you check the work afterwards?
If a buyer, a lender or an insurer wants proof, a camera re-check after the repairs gives them a fresh record.
Turn the failed report into a plan
Tell us on the contact page which findings are on the report. We visit, price each one, and mark what has to come first.
Call (909) 366-3350